BQLWF - 855 ABRASION CONTROL LIQUID PART A BLACK

  • MSDS: BQLWF
  • Manufacturer: A W CHESTERTON CO
  • Product Name: 855 ABRASION CONTROL LIQUID PART A BLACK
  • National Stock Number: 8030-00N036190
Product Identification

Product ID:855 ABRASION CONTROL LIQUID PART A BLACK
MSDS Date:03/15/1991
FSC:8030
NIIN:00N036190
Kit Part:Y
MSDS Number: BQLWF

Responsible Party
A W CHESTERTON CO
225 FALLON RD
STONEHAM, MA 02180-2999
US

Emergency Phone: 617-438-7000; 617-438-7013

Info Phone: 617-438-7000; 617-438-7013

Cage: 71431

Contractor
CHESTERTON A W CO
STONEHAM, MA 02180-9101 US

Telephone: 781-438-7000/800-535-5053

Cage: 71431

Ingredients

SILICA GEL; (SILICA)

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: 1-3%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3 TDUST


PROPANE,1,3-BIS(2,3-EPOXYPROPOXY)-2,2-DIMETHYL-; (NEOPENTYL

CAS: 17557-23-2

RTECS: TX3760000

Fraction By Weight: 1-2%


DGBA EPOXY RESINS; (BISPHENOL A DIGLYCIDYL ETHER RESIN)

CAS: 25068-38-6

RTECS: SL6475000

Fraction By Weight: 5-15%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MOD EYE & SKIN IRRITANT. MAY
CAUSE SKIN SENSIT AS EVIDENCED BY RASHES/HIVES. CHRONIC:NEOPENTYL
GLYCOL DIGLYCIDYL ETHER WAS FOUND TO BE CARCIN IN SKIN PAINTING
TESTS ON MICE & MUTAGENIC IN SOME L AB TESTS. ALTHOUGH SIGNIFICANCE
IS UNKNOWN, BISPHENOL A DIGLYCIDYL ETHER RESIN HAS BEEN SHOWN TO BE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MUTAGENIC IN SOME MICROBIAL TESTS BUT
HAS FAILED TO SHOW MUTAGENICITY IN OTHERS. CHROMOSOMAL ABERRATIONS
WERE OBSERVED IN CULTURED RAT LIVER CELLS. RPTD INHAL OF RESPIRABLE
FREE SILICA MAY CA USE SCARRING OF THE LUNGS W/COUGH & SHORTNESS OF
BREATH. A DELAYED LUNG INJURY, SILICOSIS, MAY RSLT WHICH (SUPP
DATA)
Medical Cond Aggravated by Exposure:PERSONNEL WITH PREEXISTING SKIN OR
LUNG ALLERGIES MAY BE AGGRAVATED BY EXPOSURE.

First Aid

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING. WASH SKIN WITH SOAP AND
WATER. CONSULT MD IF IRRITATION DEVELOPS. EYES: FLUSH FOR AT LEAST
15 MINUTES WITH LARGE QUANTITIES OF WATER. CONSULT MD IF IRRITATION
DEVEL OPS. INGEST: DO NOT INDUCE VOMITING. CONTACT MD IMMEDIATELY.
INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
OXYGEN/ARTIFICIAL RESPIRATION) CALL MD .

Fire Fighting

Flash Point Method:CC
Flash Point:480F,249C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM OR WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION CAN FORM ALDEHYDES,
ACIDS, OR OTHER TOXIC FUMES.

Accidental Release

Spill Release Procedures:AVOID SKIN CONTACT. CONTAIN SPILL TO A SMALL
AREA. PICK UP WITH ABSORBENT MATERIAL (E.G., SAND, SAWDUST, CLAY,
ETC.) AND TRANSFER TO A SUITABLE CONTAINER FOR DISPOSAL. KEEP OUT
OF SEWERS, STREAMS AND WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STROE IN COOL, DRY AREA.
Other Precautions:CONTAMINATED LEATHER INCLUDING SHOES CANNOT BE
DECONTAMINATED SO THEY SHOULD BE DISCARDED.

Exposure Controls

Respiratory Protection:NOT NEEDED. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENTS. IF NECESSARY, PROVIDE ADEQUATE
VENTIATION.
Protective Gloves:CHEM RESISTANT GLOVES (E.G., NEOPRENE).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IMPERVIOUS CLOTHING AS NECESSARY TO PREVENT
SKIN CONTACT.
Work Hygienic Practices:REMOVE CONTAMINATED CLOTHING IMMEDIATELY. WASH
CLOTHING BEFORE REUSE.
Supplemental Safety and Health
HLTH HAZ: IS A DISABLING, PROGRESSIVE AND SOMETIMES FATAL PULMONARY
FIBROSIS. IARC HAS CLASSIFIED SILICA AS "LIMITED EVIDENCE" OF
CARCINOGENICITY IN HUMANS.

Chemical Properties

HCC:V7
Vapor Density:>1
Spec Gravity:1.9
Evaporation Rate & Reference:<1 (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:<1

Stability

Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS AND BASES, STRONG ORGANIC BASES AND STRONG
OXIDIZERS LIKE LIQUID CHLORINE AND CONCENTRATED OXGYEN.
Stability Condition to Avoid:HEAT ABOVE 300F (149C).
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES, ACIDS AND
OTHER TOXIC FUMES.

Disposal

Waste Disposal Methods:LANDFILL SEALED CONTAINERS IN AN APPROVED AREA.
CHECK LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.